Spring hinges door spring hinges shall be adjusted so that from the open position of 70 degrees the door shall.
Fire door push plate height. Doors that do require a fire rating for example stairwell doors are required to have labeled plates if the plates extend above the bottom 16 inches of door height. Engraving door pulls to plates e ngraving on plates cutouts on plates cutout and engraving on plates note. Factory installed protection plates shall be installed in accordance with the listing of the door. Screw mounting for steel fire doors rated up to and including 3 hours and wood composite type fire doors rated up to 1 1 2 hours.
Fire doors minimum opening force allowed by code. Protective plates are usually flat sheets of metal or plastic applied to one or both sides of door faces and located in the lower 16 of the door. Metal fire doors are an economical alternative to wood fire doors when more than a 20 minute rating is required. The diameter or cross section of a pull handle remains at 19mm 35mm.
While there is an exception in nfpa 101 that allows non labeled plates up to 48 inches high on fire doors leading to hazardous areas in existing health care facilities the non. Nfpa 80 standards 2 4 5 protection plates. Low energy doors and gates usually require activation by the user through a push plate or control and are often used in moderate traffic locations as an. Maneuvering clearances must be free of protrusions the full height 80 min and changes in level other than thresholds.
Attachment of protective plates to the door faces is achieved by a variety of methods such as adhesives screws or other mechanical means that might penetrate the door face to achieve holding strength. The two most common sizes are 36 tall and 42 tall but they come in sizes from 18 to 48 usually in 2 increments armor plates on fire rated doors must be tested labeled and installed properly. Plates above this height could affect the fire performance of the door but can be permitted to be used if tested and approved. The revised guidance moves away from fixed positions for the vertical pull handles giving only minimum heights for the top fixing of 1300mm and maximum height of 1000mm and minimum height of 700mm for the bottom fixing effectively allowing a minimum 300mm pull handle.
Armor plates are used where carts are pushed through doors. Ada compliant door closers shall be adjusted so that from an open position of 90 degrees the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum. 1 1 4 standard cylinder hole cutout size 3 8 diameter standard turn knob hole other cutout sizes and styles are readily available. Be sure the pull you choose will fit on the plate allowing for cutouts and or engraving.
Steel is the sole door material to deliver a 3. Labeled fire doors control the spread of fire and smoke for up to 3 hours. As with kick plates armor plates are always installed on the push side of the door.