Fire Door Inspection Report Pdf

View the vision panel and glass from both sides of the door.
Fire door inspection report pdf. With this inspection software you can produce your final fire door inspection reports as word or pdf documents in just a few seconds back in your office without having to do extensive report writing on your computer. A fire door only works when it s closed. Www fdis co uk regular fire door inspection and maintenance is essential. Full compliance with the annual fire door assembly inspection and testing in accordance with 2010 nfpa 80 is required by january 1 2018.
Open the door and take a look at the hinges. Fire doors that are kept locked shut do not require door closers providing the door is actually kept locked shut. Check that the fire door has a working door closure system and closes 2 correctly as designed. Life safety code lsc deficiencies associated with the annual inspection and testing of fire doors should be cited under k211 means of egress general.
A fire door is completely useless if it s wedged open or can t close fully. This report provides a record of the fire door inspection report at. Fire door inspections annual fire door inspections were introduced with the adoption of the 2007 edition of nfpa 80. 25 luton square retail park accrington wa11 9qd for eon housing.
Still a checkmate fire gap gauge take a look at the edges of the door and frame. Colour coded fire door reports in seconds. Included a fire door inspection checklist and a couple of useful tables to help you keep track of your checks maintenance and remedies. It was surveyed by main surveyor of pocketsurvey on the 18th january 2019.
Open the door about halfway let go and see. The newest standard requires that fire rated doors be tested for functionality no less than annually and that a written record of the inspection be kept on file for the authority having jurisdiction ahj. For best results use a checkmate fire gap gauge or use a 1 coin to give a feel for scale this is about 3mm thick. The 2012 edition of the life safety code nfpa 101 requires facilities to complete annual fire and smoke door inspection and testing.
To help you implement the advice you are given during the week checkmate fire has compiled a downloadable fire door inspection checklist. The client eon housing instruction this fire door inspection report was undertaken in accordance with an instruction received from eon. Fire door safety week 2018 which runs from september 24th to 30th is designed to promote awareness of the importance of choosing the right fire doors and ensuring they are properly installed and maintained. Inspection and testing form nfpa inspection and testing 1 of 4 alarm notification appliances and circuit information quantity êêêêcircuit style bells horns chimes strobes speakers other specify.