Fire Door Inspection Form Pdf

Is the door undercut no more than inch.
Fire door inspection form pdf. The newest standard requires that fire rated doors be tested for functionality no less than annually and that a written record of the inspection be kept on file for the authority having jurisdiction ahj. In addition to all of the components of a fire door assembly there are. Still a checkmate fire gap gauge take a look at the edges of the door and frame. Our fire smoke door experts will provide a thorough inspection of all the doors in the building to ensure they are safe and complying with the nfpa code and prepare a detailed report on the condition and function of the fire door on your facilities.
Fire door inspections annual fire door inspections were introduced with the adoption of the 2007 edition of nfpa 80. Where door leaves other than doors arranged for automatic closing are permitted to be held open with friction door holder devices the door holder devices comply with 6 3 6 6. Check the door frame bolts hinges locks fire exit hardware door closers and other significant parts for defects in need of repair or replacement. Inspection and testing form nfpa inspection and testing 1 of 4 alarm notification appliances and circuit information quantity êêêêcircuit style bells horns chimes strobes speakers other specify.
Does the active door leaf completely close when operated from the full open position. Is the clearance from the door edge to the frame no more than 1 8 inch. For best results use a checkmate fire gap gauge or use a 1 coin to give a feel for scale this is about 3mm thick. 45 minutes 90 minutes.
Fire doors 13 inspection points per nfpa 80 2013 5 2 3 5 2 swinging fire doors with builders hardware will be inspected to verify the following. Manual fire alarm boxes ion detectors photo detectors duct detectors heat detectors waterflow switches supervisory switches other specify. We are certified to perform detailed 13 points fire doors inspection. Is the door free from missing or broken parts.
Inspect and test all rated fire door assemblies for items listed below and identify issues or concerns. Open the door and take a look at the hinges. For fire doors and other opening protectives 2010 edition section 5 2 1 and nfpa 105 standard for smoke door assemblies and other opening protectives 2010 edition section 5 2. E fire door assembly inspection checklist beginning with the 2007 edition and continuing with subsequent editions nfpa 80 standard for fire doors and other opening protectives section 5 2 inspection and testing requires all fire door assemblies to be inspected not less than annually.
Annotate images taken and generate reports on the spot using your mobile device. Does the inactive leaf close before the active leaf when a coordinator is used. This detailed fire door inspection checklist can be used to survey the overall condition of fire doors. Open the door about halfway let go and see.